The cross-linked cable thermal shrinkable termination uses the double-earthing technology, in which the steel armour earthing separates from the copper shield earthing, so that the cable trial is more reasonable.
Test the steel armour earthing and earth resistance, if it is conducted, it means the cable protection surface is damaged.
The cross-linked cable thermal shrinkable termination uses the double-earthing technology, in which the steel armour earthing separates from the copper shield earthing, so that the cable trial is more reasonable.
Test the steel armour earthing and earth resistance, if it is conducted, it means the cable protection surface is damaged.
Test the resistance between two earthings, if it is conducted, it means the external sheath is damaged; test the earth resistance of copper shield earthing, if it is conducted, it means both the internal and external protection surfaces are damaged.


| Model | Name | Applicable cable section mm2 |
| 10kv HRYN-1/1 | 10kV cross-linked cable heat shrinkable indoor termination (single-conductor) |
25-50 |
| 10kv HRYN-1/2 | 70-120 | |
| 10kv HRYN-1/3 | 150-240 | |
| 10kv HRYN-1/4 | 300-400 | |
| 10kv HRYW-1/1 | 10kV cross-linked cable heat shrinkable outdoor termination (single-conductor) |
25-50 |
| 10kv HRYW-1/2 | 70-120 | |
| 10kv HRYW-1/3 | 150-240 | |
| 10kv HRYW-1/4 | 300-400 | |
| 10kv HRYJ-1/1 | 10kV cross-linked cable heat shrinkable cable joint (single-conductor) |
25-50 |
| 10kv HRYJ-1/2 | 70-120 | |
| 10kv HRYJ-1/3 | 150-240 | |
| 10kv HRYJ-1/4 | 300-400 | |
| 10kv HRYN-3/1 | 10kV cross-linked cable heat shrinkable indoor termination (three-conductor) |
25-50 |
| 10kv HRYN-3/2 | 70-120 | |
| 10kv HRYN-3/3 | 150-240 | |
| 10kv HRYN-3/4 | 300-400 | |
| 10kv HRYW-3/1 | 10kV cross-linked cable heat shrinkable outdoor termination (three-conductor) |
25-50 |
| 10kv HRYW-3/2 | 70-120 | |
| 10kv HRYW-3/3 | 150-240 | |
| 10kv HRYW-3/4 | 300-400 | |
| 10kv HRYJ-3/1 | 10kV cross-linked cable heat shrinkable cable joint (three-conductor) |
25-50 |
| 10kv HRYJ-3/2 | 70-120 | |
| 10kv HRYJ-3/3 | 150-240 | |
| 10kv HRYJ-3/4 | 300-400 | |
| 35kv HRYN-1/1 | 35kV cross-linked cable heat shrinkable indoor termination (single-conductor) |
50-95 |
| 35kv HRYN-1/2 | 120-185 | |
| 35kv HRYN-1/3 | 240-400 | |
| 35kv HRYW-1/1 | 35kV cross-linked cable heat shrinkable outdoor termination (single-conductor) |
50-95 |
| 35kv HRYW-1/2 | 120-185 | |
| 35kv HRYW-1/3 | 240-400 | |
| 35kv HRYJ-1/1 | 35kV cross-linked cable heat shrinkable cable joint (single-conductor) |
50-95 |
| 35kv HRYJ-1/2 | 120-185 | |
| 35kv HRYJ-1/3 | 240-400 | |
| 35kv HRYN-3/1 | 35kV cross-linked cable heat shrinkable indoor termination (three-conductor) |
50-95 |
| 35kv HRYN-3/2 | 120-185 | |
| 35kv HRYN-3/3 | 240-400 | |
| 35kv HRYW-3/1 | 35kV cross-linked cable heat shrinkable outdoor termination (three-conductor) |
50-95 |
| 35kv HRYW-3/2 | 120-185 | |
| 35kv HRYW-3/3 | 240-400 | |
| 35kv HRYJ-3/1 | 35kV cross-linked cable heat shrinkable cable joint (three-conductor) |
50-95 |
| 35kv HRYJ-3/2 | 120-185 | |
| 35kv HRYJ-3/3 | 240-400 |